Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.314
Filtrar
1.
Semin Dial ; 37(3): 273-276, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38432229

RESUMEN

Mechanical problems like break or crack in Luer connectors or hubs, clamps, and tubings are common non-infectious complications of tunneled dialysis catheters (TDC), which may lead to other TDC complications and the need to insert a new catheter. These can be tackled using TDC repair kits or spare parts, which are often not available, resulting in the insertion of a new TDC that increases morbidity, TDC-related procedures, and healthcare costs. We discuss two cases of broken Luer connections of TDC, which were managed by exchanging the broken Luer connector of TDC with the similar Luer connector of a temporary dialysis catheter. Both the repaired TDCs are thereafter functioning well. This improvised technique provides an easy, effective, long-lasting option that salvages the existing TDC and reduces the cost factor.


Asunto(s)
Catéteres de Permanencia , Falla de Equipo , Diálisis Renal , Humanos , Diálisis Renal/economía , Diálisis Renal/instrumentación , Catéteres de Permanencia/efectos adversos , Catéteres de Permanencia/economía , Masculino , Fallo Renal Crónico/terapia , Persona de Mediana Edad , Cateterismo Venoso Central/efectos adversos , Cateterismo Venoso Central/economía , Cateterismo Venoso Central/instrumentación , Análisis Costo-Beneficio , Femenino , Remoción de Dispositivos/métodos , Remoción de Dispositivos/economía , Diseño de Equipo
2.
Blood Purif ; 52(6): 591-599, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37231799

RESUMEN

INTRODUCTION: The coronavirus disease 2019 (COVID-19) pandemic has caused extensive morbidity and mortality worldwide. Hemodialysis (HD) patients are both vulnerable to COVID-19 infection and tend to suffer greater disease severity and mortality. This retrospective study aimed to compare medium cut-off (MCO) and low-flux (LF) membrane dialyzers in terms of interleukin-6 (IL-6) reduction, change in inflammatory state, intradialytic complications, and mortality in chronic HD patients with COVID-19. METHOD: HD patients with a confirmed COVID-19 infection were admitted to the hospital for 10-14 days and underwent HD at the COVID-HD unit. Choice of dialyzer membrane used (MCO vs. LF) depended on the primary nephrologist(s). We collected data on demographics, baseline characteristics, laboratory results, diagnosis, treatments, HD prescription, hemodynamic status during HD, and mortality at 14 and 28 days after. RESULTS: IL-6 reduction ratio (RR) in the MCO group was 9.7 (interquartile range, 71.1) percent, which was significantly higher than that of the LF group (RR, -45.7 [interquartile range, 70.2] percent). The incidence rate of intradialytic hypotension in the MCO group was 3.846 events per 100 dialysis hours (95% confidence interval [CI], 1.954-6.856), which was significantly lower than that of the LF group (9.057; 95% CI, 5.592-13.170). Overall, mortality was not significantly different between the two groups. CONCLUSION: The MCO membrane was more effective in removing IL-6 and was better tolerated than the LF membrane. Large, randomized controlled trials are required to confirm the relative benefits of the MCO membrane, especially mortality. However, due to the COVID-19 pandemic, our results suggest that the MCO membrane may be beneficial in chronic HD patients with COVID-19.


Asunto(s)
COVID-19 , Interleucina-6 , Diálisis Renal , Humanos , COVID-19/sangre , COVID-19/inmunología , Interleucina-6/sangre , Interleucina-6/metabolismo , Diálisis Renal/instrumentación , Diálisis Renal/mortalidad , Diálisis Renal/estadística & datos numéricos , Estudios Retrospectivos , Masculino , Femenino , Adulto , Persona de Mediana Edad , Anciano , Anciano de 80 o más Años
3.
Ther Apher Dial ; 27(2): 284-292, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-36858049

RESUMEN

INTRODUCTION: Medium-cut-off (MCO) dialyzers may beneficially impact outcomes in patients on hemodialysis. METHODS: In a randomized, controlled trial in maintenance hemodialysis patients, the new Nipro ELISIO-17HX MCO dialyzer was compared to the Baxter Theranova 400 filter regarding middle molecule removal. Furthermore, the suitability of two assays for free lambda-light chain (λFLC) detection (Freelite vs. N-Latex) was verified. RESULTS: ELISIO-HX achieved slightly lower reduction ratios for ß2 -microglobulin (71.8 ± 6.0 vs. 75.3 ± 5.8%; p = 0.001), myoglobin (54.7 ± 8.6 vs. 64.9 ± 8.7%; p < 0.001), and kappa-FLC (62.1 ± 8.8 vs. 56.3 ± 7.7%; p = 0.021). λFLC reduction ratios were more conclusive with the Freelite assay and not different between ELISIO-HX and Theranova (28.4 ± 3.9 vs. 38.7 ± 13.4%; p = 0.069). The albumin loss of Theranova was considerably higher (2.14 ± 0.45 vs. 0.77 ± 0.25 g; p = 0.001) and the Global Removal ScoreLoss alb largely inferior (30.6 ± 7.4 vs. 82.4 ± 29.2%/g; p = 0.006) to ELISIO-HX. CONCLUSIONS: The new ELISIO-HX expands the choice of dialyzers for MCO hemodialysis.


Asunto(s)
Albúminas , Cefalosporinas , Diálisis Renal , Humanos , Mioglobina , Diálisis Renal/instrumentación
4.
In. García Herrera, Arístides Lázaro. Manual de enfermedades vasculares. La Habana, Editorial Ciencias Médicas, 2023. , ilus.
Monografía en Español | CUMED | ID: cum-79076
5.
Biomater Adv ; 139: 213012, 2022 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-35882156

RESUMEN

Blood purification therapy is widely used in the treatment of critically ill patients. However, most dialysis membranes are prone to thrombosis. Activated coagulation factor X (FXa) functions at the intersection of intrinsic, extrinsic, and common coagulation pathways and plays a central role in thrombogenesis. To date, few dialysis membranes that directly inhibit FXa have been reported. We modified a polyethersulfone(PES) membrane using apixaban as an FXa inhibitor and investigated the performance of this membrane (AMPES). The contact angle of the modified membrane was reduced. PWF and retention rates of BSA were increased, demonstrating good hydrophilicity and dialysis performance. Albumin adsorption was reduced from 141.8 ± 15.5 to 114.1 ± 6.9 µg cm-2. Reduced protein adsorption, especially targeted anti-FXa effect, inhibited the activation of intrinsic, extrinsic, and common coagulation pathways, as evidenced by significant prolongations of activated partial thromboplastin time, prothrombin time, and thrombin time by 145.04, 46.84 and 11.46 s, respectively. Furthermore, we determined the FXa concentration of each group, and found that the modified membrane had better anticoagulant performance through the inhibition of FXa. Favorable antiplatelet activity was also demonstrated. Thromboelastogram was used to comprehensively evaluate the anticoagulant and antithrombotic activities of the modified membrane. The R value was increased by 43.1 min, while the reduction in α angle was 42.5°. The coagulation comprehensive index reduction was 34.3. In addition, C3a and C5a were decreased by 15.3 % and 30.4 %, respectively. Furthermore, in vitro cytotoxicity and erythrocyte stability testing as well as in vivo murine experiments demonstrated the biosafety of the modified membrane. These results indicate that the AMPES dialysis membrane has an excellent potential for clinical applications.


Asunto(s)
Inhibidores del Factor Xa , Membranas Artificiales , Polímeros , Diálisis Renal , Sulfonas , Trombosis , Animales , Anticoagulantes/farmacología , Antitrombina III , Factor Xa/metabolismo , Inhibidores del Factor Xa/farmacología , Fibrinolíticos/farmacología , Humanos , Ratones , Pirazoles , Piridonas , Diálisis Renal/instrumentación , Trombosis/tratamiento farmacológico
7.
Nefrología (Madrid) ; 42(2): 1-8, Mar.-Abr, 2022.
Artículo en Español | IBECS | ID: ibc-204286

RESUMEN

Introducción : La inflamación crónica y la subyacente comorbilidad cardiovascular aún son problemas vigentes en los pacientes en hemodiálisis crónica. Existen pocos estudios que comparen la «dosis de diálisis» (Kt/V) con el grado de inflamación del paciente. Nuestro objetivo principal fue determinar si existe una relación entre los niveles séricos de proteína C reactiva (PCR) y el Kt/V utilizando la dialisancia iónica.Métodos : Estudio transversal multicéntrico. Se incluyeron 536 pacientes prevalentes en hemodiálisis crónica. Se recogieron los niveles de PCR, el índice neutrófilo-linfocito y el índice plaqueta-linfocito. Se obtuvo el Kt por dialisancia iónica y el volumen de distribución de la urea mediante la fórmula de Watson. Se dividió la muestra en 2 grupos tomando como punto de corte la mediana de PCR y se comparó la adecuación de diálisis en cada uno. Finalmente, se realizó un modelo de regresión logística para determinar las variables de mayor influencia.Resultados : La mediana de PCR fue 4,10mg/L (q25-q75: 1,67-10). El Kt/V medio fue de 1,48±0,308. El Kt/V fue menor en los pacientes incluidos en el grupo de inflamación alta (p=0,01). En la regresión logística multivariante, los niveles «altos» de PCR tuvieron una correlación directa con el Log índice neutrófilo-linfocito (p<0,001) e inversamente proporcional con los valores de albúmina sérica (p=0,014), Kt/V (p=0,037) y hierro sérico (p<0,001).Conclusión : La peor adecuación en términos de dosis de diálisis (valores de Kt/V más bajos) puede contribuir a un mayor grado de inflamación en los pacientes en hemodiálisis crónica. (AU)


Introduction : Chronic inflammation and the underlying cardiovascular comorbidity are still current problems in chronic hemodialysis patients. There are few studies comparing the “dialysis dose” (Kt/V) with the degree of inflammation in the patient. Our main objective was to determine whether there is a relationship between serum C-reactive protein (CRP) levels and the Kt/V using ionic dialysance.Methods : Multicenter cross-sectional study. A total of 536 prevalent chronic hemodialysis patients were included. CRP levels, neutrophil-lymphocyte ratio and platelet-lymphocyte ratio were collected. Kt was obtained by ionic dialysance and urea distribution volume was calculated from the Watson's formula. The sample was divided into 2 groups, taking the median CRP as the cut-off point. Dialysis adequacy obtained in each group was compared. Finally, a logistic regression model was carried out to determine the variables with the greatest influence.Results : Median CRP was 4.10mg/L (q25-q75: 1.67-10) and mean Kt/V was 1.48±0.308. Kt/V was lower in the patients included in the high inflammation group (P=.01). In the multivariate logistic regression, the “high” levels of CRP were directly correlated with the Log neutrophil-lymphocyte ratio (P<.001) and inversely proportional with serum albumin values (P=.014), Kt/V (P=.037) and serum iron (P<.001).Conclusion : The poorer adequacy in terms of dialysis doses (lower Kt/V values) may contribute to a higher degree of inflammation in chronic hemodialysis patients. (AU)


Asunto(s)
Humanos , Nefrología , Diálisis Renal/métodos , Diálisis Renal/instrumentación , Inflamación/terapia , Proteína C-Reactiva/administración & dosificación , Diálisis/instrumentación , 35063
8.
Clin J Am Soc Nephrol ; 17(3): 429-433, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-35110377

RESUMEN

Measures implemented to prevent transmission of severe acute respiratory syndrome coronavirus 2 in outpatient dialysis facilities may also help to prevent catheter-associated bloodstream infections in patients receiving hemodialysis. We used United States Renal Data System data to examine rates of antibiotic administration within dialysis facilities and rates of hospital admission for catheter-associated bloodstream infection from March 2018 through November 2020, and rates of hospitalization for sepsis, to address overall changes in hospitalization during the coronavirus disease 2019 (COVID-19) pandemic. Using logistic regression, we estimated year-over-year adjusted odds ratios of these events in 3-month intervals. During the first 6 months of the pandemic, rates of antibiotic administration were between 20% and 21% lower, and rates of hospitalization for catheter-associated bloodstream infection were between 17% and 24% lower than during corresponding periods in 2019, without significant changes in rates of hospitalization for sepsis. However, rates of catheter-associated events also decreased between 2018 and 2019, driven by reductions in facilities operated by a large dialysis provider. These data suggest that significant reductions in catheter-associated infections occurred during the pandemic, superimposed on nonpandemic-related reductions in some facilities before the pandemic. Even after the pandemic, it may be prudent to continue some COVID-19 mitigation measures to prevent catheter-associated bloodstream infections.


Asunto(s)
COVID-19/prevención & control , Infecciones Relacionadas con Catéteres/prevención & control , Cateterismo Venoso Central/efectos adversos , Catéteres de Permanencia/efectos adversos , Catéteres Venosos Centrales/efectos adversos , Control de Infecciones , Diálisis Renal/efectos adversos , Anciano , Antibacterianos/uso terapéutico , COVID-19/transmisión , COVID-19/virología , Infecciones Relacionadas con Catéteres/microbiología , Infecciones Relacionadas con Catéteres/transmisión , Cateterismo Venoso Central/instrumentación , Femenino , Hospitalización , Humanos , Masculino , Persona de Mediana Edad , Factores Protectores , Diálisis Renal/instrumentación , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Estados Unidos
9.
Food Chem Toxicol ; 160: 112773, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-34953965

RESUMEN

In hemodialysis process, membrane serves as a barrier between blood and the dialysate. The barrier when contacted by blood accompanied activation of coagulation, immunity, and cellular passageways. In the recent years, hemodialysis membrane's biocompatibility has become a issue which leads to reduce the performance during the separation process. In previous work, we developed and evaluated a cellulose-based membrane blended with polyaziridine or polyetyleneimine in formic acid for hydrophilicity, pure water flux, surface morphology, and permeation efficiency. Biocompatibility was accessed, by conducting cellular viability and cellular attachments tests. In this study, the membrane compared to a non-treated control, and cell viability revealed active and growing cell cultures after 14 days. During the cellular attachment experiment, cell cultures attached to the fabricated membrane simulated the formation of cell junctions, proving that the membrane is non-toxic and biocompatible. CA + PEI + FA membrane tested with a blood mimic fluid having density identical to renal patient's blood. The BSA concentration in the feed solution was the same as that in the blood of the renal patient. The results revealed that the CA + PEI + FA membrane was able to reject 99% bovine serum albumin (BSA) and 69.6% urea. Therefore, from biocompatibility and blood mimic fluid testing, it is confirmed that the CA + PEI + FA membrane is the finest implant for dialysis applications.


Asunto(s)
Materiales Biocompatibles/síntesis química , Celulosa/análogos & derivados , Nanopartículas/química , Polietileneimina/análogos & derivados , Diálisis Renal/instrumentación , Materiales Biocompatibles/química , Adhesión Celular , Supervivencia Celular , Celulosa/síntesis química , Celulosa/química , Formiatos/química , Tecnología Química Verde , Humanos , Interacciones Hidrofóbicas e Hidrofílicas , Membranas Artificiales , Polietileneimina/síntesis química , Polietileneimina/química
10.
Ther Apher Dial ; 26(1): 185-190, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33891365

RESUMEN

Central venous stenosis (CVS) is usually a late-diagnosed clinical entity that is common in hemodialysis patients. It causes various problems ranging from hemodialysis difficulty to loss of the arterio-venous (A-V) fistula. In the present study, we aimed to determine the effect of drug eluting balloon while excluding the influence of other variable factors by evaluating the same individuals with plain and paclitaxel-eluting balloons. This research was a prospective study of 18 symptomatic hemodialysis patients (age 50.9 ± 14.0 years, range 32-72 years; 11 male, 7 female) with CVS who underwent treatment by plain balloon angioplasty (PBA) and paclitaxel-eluting balloon angioplasty (PEBA) in our hospital from January 2016 to June 2017. First, third and sixth month central vein patency rates were compared. The median patency rates of central veins were 109.0 (range: 10-324) days after PBA and 238.5 (range: 157-501) days after PEBA (p < 0.001). There was no statistically significant difference between PBA and PEBA angioplasty in one-month patency (p Ëƒ 0.05). By contrast, a statistically significant difference was found between 3- and 6-month patency rates (p = 0.031 and p Ë‚ 0.001, respectively). Kaplan-Meier analysis revealed that the primary cumulative patency rate of PEBA was significantly longer than that of PBA (p ˂ 0.001). In this prospective study, PEBA patency is superior to PBA patency in the treatment of CVS in dialysis patients.


Asunto(s)
Angioplastia de Balón/instrumentación , Angioplastia de Balón/métodos , Oclusión de Injerto Vascular/tratamiento farmacológico , Paclitaxel/administración & dosificación , Diálisis Renal/efectos adversos , Grado de Desobstrucción Vascular/efectos de los fármacos , Adulto , Anciano , Constricción Patológica/complicaciones , Constricción Patológica/tratamiento farmacológico , Femenino , Oclusión de Injerto Vascular/etiología , Humanos , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Diálisis Renal/instrumentación , Resultado del Tratamiento , Moduladores de Tubulina/administración & dosificación
11.
J Vasc Surg ; 75(1): 248-254, 2022 01.
Artículo en Inglés | MEDLINE | ID: mdl-34314835

RESUMEN

OBJECTIVE: To evaluate the outcomes of arteriovenous fistulae (AVF), created with VasQ external support device under standard clinical practice across three vascular access clinics. METHODS: This multinational, retrospective study evaluated prospectively collected clinical outcomes of both forearm and upper arm brachiocephalic AVF (BCAVF) created using the VasQ device. Fifty-one AVF patients were pooled from three different vascular access centers in Germany, Italy, and Spain. Postprocedure outcomes were assessed by flow measurement with ultrasound examination in all centers. Primary failure, usability, patency, and intervention rates during the study period were evaluated. RESULTS: Fifty-one VasQ devices were implanted during 37 forearm (36 radiocephalic and 1 ulnar-basilic AVF) and 14 BCAVF procedures. The study population comprised mostly males (73%) and Caucasians (82%), with a mean age of 62.5 years (range, 38-84 years) and mean body mass index of 29.2. One patient died owing to access-unrelated reasons, and one patient was lost to follow-up without AVF assessment after its creation. From the remaining 49, 3 patients had a follow-up of less than 4 weeks and were excluded from maturation, primary failure, and dialysis initiation analysis (because those factors could not be evaluated yet), leaving 46 patients in this evaluation. Maturation was achieved in 91% of patients. The primary failure rate was 9%. A primary patency rate of 77% was observed at 6, 12, and 18 months. The secondary patency rate was 91% at 6 months, and 85% at 12 months and 18 months. Both primary patency and secondary patency did not differ statistically when comparing forearm AVF with BCAVF (P > .25). Successful cannulation was achieved in 86% of patients (32/37) requiring dialysis with a median time from creation to cannulation of 46 days. Of those patients, the functional patency rate was 94%. Five patients underwent seven interventions to maintain or restore patency or functionality, with an overall rate of 0.248 interventions per patient-year. CONCLUSIONS: AVFs created with VasQ external support device demonstrated promising patency and functionality outcomes in multicentric real-world setting across the two most commonly used anatomic locations.


Asunto(s)
Derivación Arteriovenosa Quirúrgica/instrumentación , Diálisis Renal/métodos , Grado de Desobstrucción Vascular , Adulto , Anciano , Anciano de 80 o más Años , Arteria Braquial/cirugía , Femenino , Estudios de Seguimiento , Antebrazo/irrigación sanguínea , Humanos , Fallo Renal Crónico/terapia , Masculino , Persona de Mediana Edad , Estudios Prospectivos , Arteria Radial/cirugía , Diálisis Renal/instrumentación , Estudios Retrospectivos , Resultado del Tratamiento
12.
Ther Apher Dial ; 26(1): 55-63, 2022 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-33928757

RESUMEN

The characteristics in dialyzer are associated with mortality in patients with end-stage renal disease (ESRD) receiving hemodialysis (HD). This study is to investigate the effects of dialyzer membranes on 3-year mortality in ESRD patients. From the long-term nationwide population database. Prevalent HD patients during 2005-2012 were enrolled. Our main analysis to calculate the effect was cox regression multivariate model. Overall, the mean age of all population (N = 73 565) was 61.0 ± 13.6 years, the observation period is 2.46 years ±0.98 within 3 years and 64.6% used polysulfone (PS), polymethyl methacrylate (PMMA) (11.6%), polyethersulfone (11.4%), and cellulose triacetate (CTA) (10.7%), ethylene vinyl alcohol (EVAL) (hazard ratio [HR] 2.72, 95% confidence interval [CI] 1.71-4.33) and CTA (HR 1.35, 95% CI 1.12-1.64) were associated with higher mortality than PS, but PMMA was not. EVAL and CTA adversely affected mortality and PMMA had no protective role. Further investigations on membrane characters on HD patients are warranted. Taipei Medical University (TMU) (TMU-JIRB (No. N201804051).


Asunto(s)
Fallo Renal Crónico/mortalidad , Fallo Renal Crónico/terapia , Membranas Artificiales , Diálisis Renal/instrumentación , Diálisis Renal/métodos , Uremia/mortalidad , Anciano , Materiales Biocompatibles , Causalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Sistema de Registros , Taiwán/epidemiología , Resultado del Tratamiento
14.
Sci Rep ; 11(1): 21771, 2021 11 05.
Artículo en Inglés | MEDLINE | ID: mdl-34741127

RESUMEN

The use of sutureless securement devices during catheterization might reduce the risk of catheter-related bloodstream infection (CRBSI) by suppressing catheter-exit infection and catheter dislodgement. However, the effectiveness of these devices in reducing CRBSI risk when securing hemodialysis catheters has not been explored. This single-center retrospective observational study examined 211 non-tunneled hemodialysis catheters (NTHCs) from 110 hemodialysis inpatients, of which 121 were secured using conventional skin sutures (Suture group) and 90 with GRIP-LOK (GRIP-LOK group). The stabilized inverse probability of treatment (SIPT)-weighting method was used to generate a new population (SIPT-weighted model) without group differences for each of the 12 predictors of CRBSI development (i.e., age, sex, dialysis history, concomitant acute kidney injury or diabetes, concurrent use of immunosuppressant drugs or aspirin, NTHC insertion site, methicillin-resistant Staphylococcus aureus, carriage, bacteremia event within 3 months before catheterization, hemoglobin level, and serum albumin titer). The effect of GRIP-LOK compared with sutures on CRBSI in the SIPT-weighted model was evaluated using univariate SIPT-weighted Cox proportional regression analysis, which showed a significant CRBSI suppression effect of GRIP-LOK compared with sutures (hazard ratio: 0.17 [95% CI 0.04-0.78], p = 0.023). GRIP-LOK affords a lower risk of CRBSI due to indwelling NTHCs than conventional securement using sutures.


Asunto(s)
Infecciones Relacionadas con Catéteres/prevención & control , Diálisis Renal/instrumentación , Sepsis/prevención & control , Dispositivos de Cierre Vascular/estadística & datos numéricos , Anciano , Anciano de 80 o más Años , Femenino , Humanos , Masculino , Persona de Mediana Edad , Estudios Retrospectivos
15.
Sci Rep ; 11(1): 23080, 2021 11 29.
Artículo en Inglés | MEDLINE | ID: mdl-34845257

RESUMEN

Chronic kidney disease affects millions of people around the globe and many patients rely on hemodialysis (HD) to survive. HD is associated with undesired life-threatening side effects that are linked to membrane biocompatibility and clinical operating conditions. The present study develops a mathematical model to predict the inflammatory biomarkers released in HD patients based on membrane morphology, chemistry, and interaction affinity. Based on the morphological characteristics of two clinical-grade HD membrane modules (CTA and PAES-PVP) commonly used in Canadian hospitals, a molecular docking study, and the release of inflammatory cytokines during HD and in vitro incubation experiments, we develop five sets of equations that describe the concentration of eight biomarkers (serpin/antithrombin-III, properdin, C5a, 1L-1α, 1L-1ß, C5b-9, IL6, vWF). The equations developed are functions of membrane properties (pore size, roughness, chemical composition, affinity to fibrinogen, and surface charge) and HD operating conditions (blood flow rate, Qb, and treatment time, t). We expand our model based on available clinical data and increase its range of applicability in terms of flow rate and treatment time. We also modify the original equations to expand their range of applicability in terms of membrane materials, allowing the prediction and validation of the inflammatory response of several clinical and synthesized membrane materials. Our affinity-based model solely relies on theoretical values of molecular docking, which can significantly reduce the experimental load related to the development of more biocompatible materials. Our model predictions agree with experimental clinical data and can guide the development of novel materials and support evidence-based membrane synthesis of HD membranes, reducing the need for trial-and-error approaches.


Asunto(s)
Fallo Renal Crónico/sangre , Fallo Renal Crónico/terapia , Membranas Artificiales , Modelos Teóricos , Diálisis Renal/métodos , Adulto , Materiales Biocompatibles/química , Biomarcadores/metabolismo , Canadá , Activación de Complemento , Femenino , Fibrinógeno/química , Hospitales , Humanos , Hidrodinámica , Inflamación , Cinética , Ligandos , Masculino , Microscopía de Fuerza Atómica , Persona de Mediana Edad , Simulación del Acoplamiento Molecular , Espectroscopía de Fotoelectrones , Diálisis Renal/instrumentación , Reproducibilidad de los Resultados
16.
Int J Biol Macromol ; 191: 872-880, 2021 Nov 30.
Artículo en Inglés | MEDLINE | ID: mdl-34571131

RESUMEN

Mixed matrix membranes (MMMs) of cellulose acetate/poly(vinylpyrrolidone) (CA/PVP) infused with acid functionalized multiwall carbon nanotubes (f-MWCNTs) were fabricated by an immersion phase separation technique for hemodialysis application. Membranes were characterized using FTIR, water uptake, contact angle, TGA, DMA and SEM analysis. The FTIR was used to confirm the bonding interaction between CA/PVP membrane matrix and f-MWCNTs. Upon addition of f-MWCNTs, TGA thermograms and glass transition temperature indicated improved thermal stability of MMMs. The surface morphological analysis demonstrated revealed uniform distribution of f-MWCNTs and asymmetric membrane structure. The water uptake and contact angle confirmed that hydrophilicity was increased after incorporation of f-MWCNTs. The membranes demonstrated enhancement in water permeate flux, bovine serum albumin (BSA) rejection with the infusion of f-MWCNTs; whereas BSA based anti-fouling analysis using flux recovery ratio test shown up to 8.4% improvement. The urea and creatinine clearance performance of MMMs were evaluated by dialysis experiment. It has been found that f-MWCNTs integrated membranes demonstrated the higher urea and creatinine clearance with increase of 12.6% and 10.5% in comparison to the neat CA/PVP membrane. Thus, the prepared CA/PVP membranes embedded with f-MWCNTs can be employed for wide range of dialysis applications.


Asunto(s)
Celulosa/análogos & derivados , Membranas Artificiales , Nanotubos de Carbono/química , Povidona/química , Diálisis Renal/instrumentación , Celulosa/química , Creatinina/química , Interacciones Hidrofóbicas e Hidrofílicas , Diálisis Renal/métodos
17.
Artif Organs ; 45(12): 1522-1532, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34309036

RESUMEN

Disturbed oxygenation is foremost the leading clinical presentation in COVID-19 patients. However, a small proportion also develop carbon dioxide removal problems. The Advanced Organ Support (ADVOS) therapy (ADVITOS GmbH, Munich, Germany) uses a less invasive approach by combining extracorporeal CO2 -removal and multiple organ support for the liver and the kidneys in a single hemodialysis device. The aim of our study is to evaluate the ADVOS system as treatment option in-COVID-19 patients with multi-organ failure and carbon dioxide removal problems. COVID-19 patients suffering from severe respiratory insufficiency, receiving at least two treatments with the ADVOS multi system (ADVITOS GmbH, Munich, Germany), were eligible for study inclusion. Briefly, these included patients with acute kidney injury (AKI) according to KDIGO guidelines, and moderate or severe ARDS according to the Berlin definition, who were on invasive mechanical ventilation for more than 72 hours. In total, nine COVID-19 patients (137 ADVOS treatment sessions with a median of 10 treatments per patient) with moderate to severe ARDS and carbon dioxide removal problems were analyzed. During the ADVOS treatments, a rapid correction of acid-base balance and a continuous CO2 removal could be observed. We observed a median continuous CO2 removal of 49.2 mL/min (IQR: 26.9-72.3 mL/min) with some treatments achieving up to 160 mL/min. The CO2 removal significantly correlated with blood flow (Pearson 0.421; P < .001), PaCO2 (0.341, P < .001) and HCO 3 - levels (0.568, P < .001) at the start of the treatment. The continuous treatment led to a significant reduction in PaCO2 from baseline to the last ADVOS treatment. In conclusion, it was feasible to remove CO2 using the ADVOS system in our cohort of COVID-19 patients with acute respiratory distress syndrome and multiorgan failure. This efficient removal of CO2 was achieved at blood flows up to 300 mL/min using a conventional hemodialysis catheter and without a membrane lung or a gas phase.


Asunto(s)
COVID-19/terapia , Dióxido de Carbono/sangre , Circulación Extracorporea/instrumentación , Pulmón/fisiopatología , Insuficiencia Multiorgánica/terapia , Diálisis Renal/instrumentación , Respiración Artificial , Anciano , COVID-19/sangre , COVID-19/diagnóstico , COVID-19/fisiopatología , Enfermedad Crítica , Circulación Extracorporea/efectos adversos , Femenino , Humanos , Masculino , Persona de Mediana Edad , Insuficiencia Multiorgánica/sangre , Insuficiencia Multiorgánica/diagnóstico , Insuficiencia Multiorgánica/fisiopatología , Diálisis Renal/efectos adversos , Respiración Artificial/efectos adversos , Factores de Tiempo , Resultado del Tratamiento
18.
Br J Nurs ; 30(14): S24-S32, 2021 Jul 22.
Artículo en Inglés | MEDLINE | ID: mdl-34288746

RESUMEN

HIGHLIGHTS: 2% taurolidine catheter lock solution without additives is safe and efficient. CRBSI and dysfunction rates compare favorably against other studies in hemodialysis. BACKGROUND: In hemodialysis patients, catheter-related bloodstream infection (CRBSI) and catheter dysfunction are common and cause significant morbidity, mortality, and costs. Catheter lock solutions reduce CRBSI and catheter dysfunction rates, but solutions containing heparin, citrate, or antibiotics are associated with adverse effects. Due to its antimicrobial and antithrombotic properties and benign safety profile, taurolidine is suitable for use in catheter lock solutions. In this study the effectiveness and safety of a catheter lock solution containing 2% taurolidine without citrate or heparin (TauroSept®, Geistlich Pharma AG, Wolhusen, Switzerland) in hemodialysis patients were investigated for the first time. METHODS: Data from 21 patients receiving chronic hemodialysis via tunneled central venous catheters with 2% taurolidine solution as a catheter lock were analyzed in a single-center retrospective study and compared with the existing literature in a review. The primary endpoint was CRBSI rate. Secondary endpoints included catheter dysfunction, treatment, and costs; catheter technical problems, resolution, and costs; and adverse events. Data were compared to outcomes with standard lock solutions in the literature. RESULTS: No CRBSIs occurred during the observation period of 5,639 catheter days. The catheter dysfunction rate was 0.71 per 1,000 catheter days, and the catheter dysfunction treatment costs were CHF (Swiss Franc) 543 per patient. No technical problems or adverse events related to the use of 2% taurolidine-containing catheter lock solution were observed. These results compare favorably with other catheter lock solutions. CONCLUSIONS: A solution containing 2% taurolidine seems suitable as a hemodialysis catheter lock. In a Swiss cohort, it prevented CRBSI, limited catheter dysfunction, and was cost-efficient.


Asunto(s)
Bacteriemia , Infecciones Relacionadas con Catéteres , Catéteres Venosos Centrales , Taurina/análogos & derivados , Tiadiazinas , Bacteriemia/etiología , Bacteriemia/prevención & control , Infecciones Relacionadas con Catéteres/prevención & control , Catéteres Venosos Centrales/efectos adversos , Falla de Equipo , Humanos , Diálisis Renal/instrumentación , Estudios Retrospectivos , Suiza , Taurina/uso terapéutico , Tiadiazinas/uso terapéutico
19.
J Clin Lab Anal ; 35(8): e23886, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-34173983

RESUMEN

AIMS: To assess the relation of high serum OPG level and carotid atherosclerosis in maintenance hemodialysis (MHD) patients using low-flux reused dialyzer. MATERIALS AND METHODS: We examined 209 MHD patients with and without carotid atherosclerosis (83 patients and 126 patients) to establish the relation between OPG and atherosclerosis. RESULTS: The proportion of carotid atherosclerosis was 39.7%. The median serum OPG level was 45.3 pmol/L. Serum OPG had a good predicting value for atherosclerosis in MHD patients using low-flux reused dialyzer (AUC = 0.934, p < 0.001, cutoff value = 43.35 pmol/L, Se = 81.3%, Sp = 90.9%). CONCLUSIONS: In this study, serum OPG had a good predicting value for atherosclerosis in MHD patients using low-flux reused dialyzer.


Asunto(s)
Aterosclerosis/sangre , Enfermedades de las Arterias Carótidas/sangre , Osteoprotegerina/sangre , Diálisis Renal/instrumentación , Adulto , Femenino , Humanos , Modelos Logísticos , Masculino , Persona de Mediana Edad , Diálisis Renal/métodos
20.
Am J Nephrol ; 52(6): 479-486, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-34111865

RESUMEN

INTRODUCTION: Successful cannulation of an arteriovenous fistula (AVF) is important in patients starting hemodialysis (HD). Metal needles have been used for decades, but the usefulness of plastic cannulae has recently been demonstrated as a new technique. METHODS: This was a prospective, randomized, open-label study of incident HD patients. Eligible patients were randomized into 2 groups in a 1:1 ratio (n = 45/group). Maturation of the AVF was confirmed using Doppler ultrasound prior to first needling, and 2 well-trained nurses implemented the AVF cannulation. The primary endpoint was the initial cannulation failure rate, defined as the failure of successful completion of 3 consecutive dialysis sessions. The secondary endpoints were time for hemostasis at the end of HD, degree of patients' pain, degree of cannulation difficulty felt by the nursing staffs, and achieving optimal HD adequacy. RESULTS: The mean elapsed time from AVF creation to the first cannulation was 48.1 ± 16.7 days. A total of 17 cases of cannulation failure occurred, and the failure risk tended to be higher in the metal needle group than the plastic cannula group (hazard ratio 2.6, 95% confidence interval 0.95-7.41) after adjusting for age, gender, comorbidities, and AVF location. The overall incidence of vessel injury was higher and time for hemostasis was significantly longer in the metal group than the plastic group. The use of plastic cannula was associated with a better HD adequacy compared to a metal needle. However, the patients' pain score (p = 0.004) and nursing staff's cannulation difficulty score (p = 0.084) were higher in the plastic group, emphasizing the great importance of practice using plastic cannulae. CONCLUSION: The vascular outcomes of plastic cannulae were much favorable compared to metal needles in incident HD patients. The use of plastic cannulae could be a new and innovative way to improve the quality of dialysis.


Asunto(s)
Cánula , Cateterismo Periférico/instrumentación , Agujas , Diálisis Renal/instrumentación , Anciano , Derivación Arteriovenosa Quirúrgica , Vasos Sanguíneos/lesiones , Cánula/efectos adversos , Femenino , Hemostasis , Humanos , Masculino , Metales , Persona de Mediana Edad , Agujas/efectos adversos , Dolor Asociado a Procedimientos Médicos/etiología , Plásticos , Estudios Prospectivos , Factores de Tiempo
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...